Contact us / Kontakt:
SES GmbH Analysesysteme Friedhofstr. 7-9 55234 Bechenheim / Germany Tel.: +49 (0) 6736 1301 Fax: +49 (0) 6736 1305 e-Mail: support@tlc-fid.com
I-3202 semi automated Spotter
SES Model 3202 Spotter for TLC-FID techniques is a precision instrument specially developed for applying sample solutions onto the sintered silica gel surface of a ROD. The smaller and more concentrated the sample spot, the better the resolution obtained after development of the ROD in a TLC chamber. The reproducibility of quantitative and qualitative analyses with a TLC-FID Analyser is closely related to the accurate application of a known quantity of sample onto the surface of a ROD in the form of a micro spot. With the "Autospotter" it is possible to apply between 0.020 and 10 micro liters of sample solution. The spotting is electronically controlled through a small external microprocessor module, with a precision of better than 0.5 %.
Chromarod Dryer
Rod Dryer eco Our smalest Rod Dryer, take just 31x 26 x 39 cm on your table. He have space for 2 Rods Holder and can be heat up from 50-200°C. He is only available with 220-240V.
Rod Dryer C8 Our Rods Dryer Oven C8 ist specialy designed for customers who wants to dry a lot numbers of RODs in the same time. He can hold up to 8 Rod Holders in once. He works with usual Heating and with additional infrared heating. They need space of 47x40x32 cm on your table. He is only available with 220-240V.
Rod Dryer ED23 Our Rods Dryer Oven Ed23 is the standard Dryer. He have a very good quality , is eays to use and can hold up to 6 Rod Holders in once. They need space of 50 x 45 x 55 cm on your table. He is availablewith 110-125V and 220-240V.
Rods and Rod Holders
The Rod, developed for a TLC-FID Analysers. It is a thin layer in the form of thin quarz rod evenly applied and sintered inorganic binder and adsorbent on it. Usually the cleaning and activation of Rods can be used repeatedly. The Rods give excellent separability of components and exhibit stable reproducibility. Special types of thin-layers, such as those suitable for seperating triglycerides in accor- dance with their unsaturation degrees or glyceride isomers, can be easily prepared simply by immersing the rods in silver nitrate or boric acid solution respectively.
Helpfull Accessories
Silica Rods Standard Mixtures for Lipids 8001 Standard Mixtures for Heavy Oil 8011 Development Tank Filter Paper for Development Tank Rod Storage Chamber Rod Holder Rod Viewer Panel Rod Dryer TK12 eco
TLC-FID. com
SES GmbH - Analytical Systems
products for Thin Layer Chromatography with FID Detector